Configuring Alerts for SGM and Chassis Events (asg alert)
The asg alert utility is an interactive wizard used to configure alerts for SGM and Chassis events. Event types can include hardware failure, recovery, and performance related events. You can also create events for other, general events.
An alert is sent when an event occurs. For example, an alert is generated when the value of a hardware resource is greater than the threshold. The alert message includes the Chassis ID, SGM ID and/or unit ID, as applicable.
The wizard includes these options:
Option
|
Description
|
Full Configuration Wizard
|
Create a new alert
|
Edit Configuration
|
Change an existing alert
|
Show Configuration
|
Show existing alert configurations
|
Run Test
|
Run a test simulation to make sure that the alert works correctly
|
To create or change an alert:
- Run:
> asg alert
- Select and configure these parameters as prompted by the wizard:
- Alert type and related parameters
- Event types
- Alert mode
These sections include details about the alert parameters that you configure with the wizard.
SMS alert parameters
- - Fully qualified URL to your SMS provider based on this syntax.
- (Optional) – Necessary only if your Security Gateway requires a proxy server to reach the SMS provider
- - Maximum number of SMS messages sent per hour. When there are too many messages, the others are sent together as one message.
- - Custom prefix for SMS messages
- - Configure one or more SMTP servers to which the email alerts will be sent.
- - Configure one or more recipient email addresses for each SMTP servers.
- - Run a periodic test to make sure that there is connectivity with the SNMP servers. If there is no connectivity, alert messages are saved and sent in one email when connectivity is restored.
- - Define the interval, in minutes, between connectivity tests.
- - Configure a sender email address for email alerts.
- - Subject header text for the email alert.
- - Enter user-defined text for the alert message. .
SNMP alert parameters
Define one or more SNMP managers to get SNMP traps sent from the Security Gateway. For each manager, configure these parameters as prompted:
: Some parameters do not show, based on your settings.
- - Configure a name for your SNMP manager (unique)
- - Configure the manager IP address (trap receiver)
- - Select the SNMP version to use (v2cv3)
- - If using SNMP v3 authentication, you must configure this.
- - Unique SNMP v3 engine ID used by your system. Default = [0x80000000010203EA].
- l - MD5 or SHA.
- - Enter a privacy password.
- - DES or AES.
- - Enter a privacy password.
- - Custom text for the SNMP trap messages.
- - Configure the community string for the SNMP manager.
Log alert parameters
There are no configurable parameters for log alerts
Event types
You can select one or more event types:
- One event type
- A comma-delimited list of more than one event type
all for all event types.
-----------------------------------
1 | SGM State
2 | Chassis State
3 | Port State
4 | Pingable Hosts State
5 | System Monitor Daemon
6 | Route State
7 | Diagnostics
Hardware Monitor events:
8 | Fans
9 | SSM
10 | CMM
11 | Power Supplies
12 | CPU Temperature
Performance events:
13 | Concurrent Connections
14 | Connection Rate
15 | Packet Rate
16 | Throughput
17 | CPU Load
18 | Hard Drive Utilization
19 | Memory Utilization
Alert Modes
- - An alert is sent for the selected events
- - No alert is sent for the selected events
- - A log entry is generated instead of an alert
|