Resetting SIC on a Security Gateway or VSX Gateway (VS0)

The procedure for resetting SIC on a Security Gateway or VSX Gateway (VS0) has a few stages.

Stage 1: Initializing SIC on the Gateway

  1. Use a serial console to connect to the gateway.
  2. Enter the Expert shell
  3. Find out which SGM is the SMO.Run
    asg stat –i tasks
  4. Run:
    g_cpconfig sic init <activation key>

    Notes

    • The SIC Reset procedure lasts several (about 3 to 5) minutes.
    • During the SIC reset procedure:
    • On a Security Gateway: All SGMs other than the SMO reboot
    • On a VSX Gateway: It is Mandatory to perform Stage 2 immediately when the SIC procedure is done.

Stage 2: Initializing SIC In SmartDashboard

  1. On the Gateway object, open the General Properties > Communication window.
  2. Click Reset.
  3. Enter the same activation key used in Stage 1.
  4. Click Initialize.
  5. On a VSX Gateway:
    1. Install Policy on the VSX gateway.
    2. At the serial console connection to the gateway, press ’c’ to complete procedure.
      Note At this stage, all SGMs except the SMO do a reboot.

Stage 3. Verifying Trust is established on the Gateway

Run g_cpconfig sic state:

[Expert@61000/41000 Security System-Box:0]# g_cpconfig sic state	
-*- 6 blades: 1_01 1_02 1_03 2_01 2_02 2_03 -*-
Trust State: Trust established
 
Top of Page ©2014 Check Point Software Technologies Ltd. All rights reserved. Download Complete PDF Send Feedback Print