Upgrading SSM60 to
SSM160
To
prepare the 61000/41000 Security
System for the SSM upgrade:
- Connect to the 61000/41000
Security System.
- Save the output from the
following:
>
asg if
>
asg stat -v
>
asg diag
>
asg_version
- Create a backup of the
configuration:
> g_all backup_system
backup ssm60
- Make sure the SSM160s have
the correct firmware version.
- R75.035 is only
compatible with SSM160 firmware 2.4.B6
- R75.050 is only
compatible with SSM160 firmware 2.4.B11
- R75.40VS is only
compatible with SSM160 firmware 2.4.B27.2
- R76SP and higher are
only compatible with SSM160 firmware 2.4.C10
To
replace the SSM on Chassis B:
- Disconnect the Chassis B
cables from the network.
- Turn off all SGMs in the
Chassis.
- Replace both SSM60's with
SSM160's in the disconnected Chassis.
- Wait for both SSM160 to
boot up. This can take a few minutes.
- Make sure that the SSM160s
have the correct firmware installed.
- If the SSM160s do not have
the correct firmware installed, upgrade the
firmware.
- Turn on all the SGMs.
- Make sure that all SGMs are
UP:
>
asg_monitor
This step can take a few
minutes.
- Run:
>
asg dxl dist_mode set –f
- Reconfigure management
interfaces if necessary.
- Make sure the SSM firmware
version is correct:
>
asg_version
- Run:
>
asg if
>
asg stat -v
>
asg diag
>
asg_version
- Make sure that the output
matches the results from the preparation stage.
- Make sure that all SGMs are
UP and the Chassis is Active.
- Run:
>
ethtool eth1-[1-16] and ethtool eth2-[1-16]
>
asg hw_monitor
>
g_fw ctl set int fwha_gratuitous_arp_timeout
100
- Make sure that all
interfaces are set up correctly.
To upgrade the SSM on
Chassis A:
- Disconnect the cables from
the Chassis A.
- Connect the cables to the
new upgraded Chassis B. Take into account the
change in the management interface in step 15.
- Optional:
Run:
>
asg_chassis_ctrl clear_mac_learning
- Make sure that traffic is
processed by the new Active upgraded Chassis B.
At this point, you can
roll back to Chassis B if needed.
- Do steps 2-16 on Chassis A
in the earlier procedure.
- Connect the Sync network
cables between the Chassis.
- Connect the management and
traffic interface cables. Take into account the
change in the management interface in step 15.
- Make sure that both Chassis
communicate.
- Run:
>
asg stat –v
- Make sure that the Active
& Standby Chassis and all SGMs are UP.
- Get the topology and
install the policy.
- Make sure the new
management port configuration takes effect.
- Configure GARPs on Chassis
B to their defaults:
>
g_fw ctl set int fwha_gratuitous_arp_timeout
600
|
|