Upgrade Using Boot Loader
To upgrade the Quantum Spark Appliance using U-boot (boot loader):
|
Note - In 1570 / 1590, Bootloader is supported only through the DMZ port and is not available through the LAN ports. |
-
Connect to the console port on the appliance with (use the serial console connection on the back panel of the appliance).
-
Reboot the appliance.
-
During boot, when the applicable message appears, press CTRL+C.
The Gaia Embedded Boot Menu appears:
Welcome to Gaia Embedded Boot Menu:
1. Start in normal Mode
2. Start in debug Mode
3. Start in maintenance Mode
4. Restore to Factory Defaults (local)
5. Install/Update Image/Boot-Loader from Network
6. Restart Boot-Loader
7. Run Hardware diagnostics
8. Install DSL Firmware/Upload preset configuration file
Please enter your selection (press ENTER to finish):
-
Press 5 to select the option Install/Update Image/Boot-Loader from Network.
-
You are asked if you want to load the image manually from a TFTP server, or if you want to use automatic mode with a BOOTP server.
-
If you select manual mode, you are asked to fill in the IP of the Quantum Spark Appliance, the IP of the TFTP server, and the image name.
-
If you select automatic mode, the procedure starts automatically to search for the BOOTP server.
-
While in the menu mode, press CTRL+C again to return to the Boot Loader menu.
During the upgrade, the Power LED blinks blue to show progress. This takes up to a minute.
When the upgrade is successfully completed, the Power LED is solid blue, and the appliance waits for you to press a key. Error in the upgrade process is indicated if the Power LED is red.