show diag

Description

Shows information about your appliance:

  • Firmware version

  • Serial number

  • MAC Addresses

  • Hardware capabilities (1 - SD card, 2 - Wireless, 3 - DSL, 4 - POE, 5 - Cellular)

  • Voltages

  • Temperatures for CPU and RAM (DDR)

Syntax

show diag

Example Output

HostName> show diag


Current system info
-----------------------------------
Current image name: R80_XXXXXXXXX_20_35
Current image version: XXX
Previous image name: R80_XXXXXXXXX_20_35
Previous image version: XXXX
Default image name: R80_XXXXXXXXX_20_35
Default image version: XXX
Bootloader version: XXXXXXXX
HW version : XXX
Serial number : XXXXXXXXXX
HW MAC Address: 00:1C:XX:XX:XX:YY
LAN MAC Address: 00:1C:XX:XX:XX:ZZ
Unit version: 1
Unit model: V0
Marketing capabilities: 0
Management opaque: XXX=:XXX/XXX=:XXX
Hardware capabilities: 2 - Wireless
RTC status: OK
Voltage 3V3:            3.3484V - OK (valid: 3.1500V ~ 3.4500V)
Voltage 12V:            12.3000V - OK (valid: 11.4000V ~ 12.6000V)
Voltage 1V8:            1.8240V - OK (valid: 1.7000V ~ 1.9000V)
Voltage 0V9:            0.9570V - OK (valid: 0.8100V ~ 1.1000V)
Voltage 1V2:            1.2050V - OK (valid: 1.1600V ~ 1.2400V)
Voltage 1V2_SRM:                1.2122V - OK (valid: 1.1600V ~ 1.2400V)
CPU Temperature:                47.0000C - OK (valid: 0.0000C ~ 82.0000C)
CPU Temperature(internal):              52.2650C - OK (valid: 0.0000C ~ 100.0000C)
DDR Temperature:                47.0000C - OK (valid: 0.0000C ~ 80.0000C)
EMMC % of device lifetime used:         0-10% - OK (valid: 0 ~ 90%)
EMMC EOL status:                Normal - OK
Branding file: N/A
Preset File installed: no
-----------------------------------


HostName>