show diag
Description
Shows information about your appliance:
-
Firmware version
-
Serial number
-
MAC Addresses
-
Hardware capabilities (1 - SD card, 2 - Wireless, 3 - DSL, 4 - POE, 5 - Cellular)
-
Voltages
-
Temperatures for CPU and RAM (DDR)
Syntax
|
Example Output
HostName> show diag Current system info ----------------------------------- Current image name: R80_XXXXXXXXX_20_35 Current image version: XXX Previous image name: R80_XXXXXXXXX_20_35 Previous image version: XXXX Default image name: R80_XXXXXXXXX_20_35 Default image version: XXX Bootloader version: XXXXXXXX HW version : XXX Serial number : XXXXXXXXXX HW MAC Address: 00:1C:XX:XX:XX:YY LAN MAC Address: 00:1C:XX:XX:XX:ZZ Unit version: 1 Unit model: V0 Marketing capabilities: 0 Management opaque: XXX=:XXX/XXX=:XXX Hardware capabilities: 2 - Wireless RTC status: OK Voltage 3V3: 3.3484V - OK (valid: 3.1500V ~ 3.4500V) Voltage 12V: 12.3000V - OK (valid: 11.4000V ~ 12.6000V) Voltage 1V8: 1.8240V - OK (valid: 1.7000V ~ 1.9000V) Voltage 0V9: 0.9570V - OK (valid: 0.8100V ~ 1.1000V) Voltage 1V2: 1.2050V - OK (valid: 1.1600V ~ 1.2400V) Voltage 1V2_SRM: 1.2122V - OK (valid: 1.1600V ~ 1.2400V) CPU Temperature: 47.0000C - OK (valid: 0.0000C ~ 82.0000C) CPU Temperature(internal): 52.2650C - OK (valid: 0.0000C ~ 100.0000C) DDR Temperature: 47.0000C - OK (valid: 0.0000C ~ 80.0000C) EMMC % of device lifetime used: 0-10% - OK (valid: 0 ~ 90%) EMMC EOL status: Normal - OK Branding file: N/A Preset File installed: no ----------------------------------- HostName> |