Installing a Hotfix on Dual Chassis
This procedure describes the Full Connectivity installation of an Offline CPUSE package on Dual Chassis.
Important Notes
-
It is not supported to upgrade the CPUSE Agent on SGMs in a Security Group.
-
This procedure applies to Security Groups in Security Gateway mode and VSX mode.
In VSX mode, you must run all the commands in the context of VS0.
-
This procedure keeps the current connections.
-
If you finished a clean install on this chassis, then you can install a Jumbo Hotfix Accumulator only after you run the Gaia First Time Configuration Wizard.
-
Do not install the hotfix on all the SGMs at the same time.
If you do so with the command below, traffic stops passing through all SGMs until the hotfix is installed:
installer install <Number of CPUSE Package> member_ids all
-
With this procedure, you install the hotfix on one chassis at one time.
The other chassis continues to handle traffic.
-
You install the hotfix on "Standby Chassis A" from an SGM in "Standby Chassis A".
-
You failover all connections from "Standby Chassis B" to "Standby Chassis A".
-
You install the hotfix on "Standby Chassis B" from an SGM in "Standby Chassis B".
In the procedures below:
-
"Standby Chassis A" is the Standby Chassis (
chassis1
) -
"Standby Chassis B" is the Active Chassis (
chassis2
)
-
|
Best Practice - Perform this procedure over the serial console. |
Part 1 - Preliminary Steps
In this part, you import the CPUSE package and make sure it can be installed.

Step |
Instructions |
||
---|---|---|---|
1 |
Make sure you have the applicable CPUSE offline package (TGZ file) or the exported CPUSE package (TAR file). |
||
2 |
Transfer the CPUSE offline or exported package to the Chassis (into some directory, for example: |
||
3 |
Connect to the command line on each chassis. |
||
4 |
Log in to Gaia Clish. |
||
5 |
Go to the Gaia gClish:
|
||
6 |
Import the CPUSE package from the hard disk:
Example:
|
||
7 |
Show the imported CPUSE packages:
|
||
8 |
Make sure the imported CPUSE package can be installed on this Chassis:
Example: |
Part 2 - Installing the Hotfix on Standby Chassis A
In this part, you install the Hotfix on all SGMs on the Standby "Standby Chassis A" (chassis1
).

Step |
Instructions |
||
---|---|---|---|
9 |
Connect to the command line on the Standby Chassis (in our example, Standby Chassis A). |
||
10 |
Log in to the Expert mode. |
||
11 |
Set the state of the Standby Chassis to "down":
Example:
|
||
12 |
Connect to one of the Security Group Members in the Logical Group "A":
|
||
13 |
Go to the Gaia gClish:
|
||
14 |
Install the CPUSE hotfix package on the Standby Chassis:
Example: |
||
15 |
Exit from Gaia gClish to the Expert mode:
|
||
16 |
Monitor the system until SGMs on the Standby Chassis are in the UP state and enforce the Security Policy again:
|
||
17 |
Set the state of the Standby Chassis to "up":
Example:
|
||
18 |
Monitor the system until SGMs on the Standby Chassis are in the UP state and enforce the Security Policy again:
|
Part 3 - Failing Over from Standby Chassis B to Standby Chassis A
In this part, you fail over all connections from the Active "Standby Chassis B" to the Standby "Standby Chassis A".

Step |
Instructions |
||
---|---|---|---|
19 |
Connect to the command line on the Active Chassis (in our example, Standby Chassis B). |
||
20 |
Log in to the Expert mode. |
||
21 |
Set the state of the Active Chassis to "down":
Example:
|
Part 4 - Installing the Hotfix on Standby Chassis B
In this part, you install the Hotfix on all SGMs on the former Active "Standby Chassis B" (chassis2
).

Step |
Instructions |
||||
---|---|---|---|---|---|
22 |
Connect to one of the Security Group Members in the Logical Group "B":
|
||||
23 |
Go to the Gaia gClish:
|
||||
24 |
Install the CPUSE hotfix package on the former Active Chassis (in our example, Standby Chassis B):
Example: |
||||
25 |
Exit from Gaia Clish to the Expert mode:
|
||||
26 |
Monitor the system until SGMs on the former Active Chassis are in the UP state and enforce the Security Policy again:
|
||||
27 |
Set the state of the former Active Chassis to "up":
Example:
|
||||
28 |
Monitor the system until SGMs on the former Active Chassis are in the UP state and enforce the Security Policy again:
|