Maximum Supported Items
This section provides the maximum supported numbers for various hardware and software items.
Management Server
Item |
Maximum Number |
Hard Limit |
Comment |
---|---|---|---|
Network objects in all Domains |
1,000,000 |
Yes |
This applies to objects of these types - Security Gateway Dedicated Check Point server that runs Check Point software to inspect traffic and enforce Security Policies for connected network resources., Cluster Two or more Security Gateways that work together in a redundant configuration - High Availability, or Load Sharing., Network, Host, Group, Address Range, Dynamic Object Special object type, whose IP address is not known in advance. The Security Gateway resolves the IP address of this object in real time., Wildcard Object, Security Zone, LSV Profile, Domain, Interoperable Device, VoIP Domain, Logical Server, OSE Device, Access Point Name. |
Network objects in each Domain |
100,000 |
No |
|
Security Gateway objects in each Domain |
300 and 500 |
No |
To make sure the Management Server Check Point Single-Domain Security Management Server or a Multi-Domain Security Management Server. is responsive when you manage more than 300 Security Gateways, it is necessary to disable the three LSM Add-ons as described in sk135972 ( |
Objects in each Group object |
12,000 |
Yes |
|
Rules in each policy |
28,000 |
Yes |
To ensure optimal Security Gateway responsiveness, we recommend configuring a maximum of 20,000 rules in a policy. While the Security Gateway can support more rules than 20,000 rules, the smaller the number of rules in the installed policy, the more responsive the Security Gateway is. |
Changes in one session |
100 |
No |
To ensure optimal Management Server responsiveness, we recommend making 100 or fewer changes in each session (although the Management Server can support more than 500 changes at a time). |
Interfaces in each Security Gateway |
200 |
No |
To ensure optimal SmartConsole Check Point GUI application used to manage a Check Point environment - configure Security Policies, configure devices, monitor products and events, install updates, and so on. responsiveness, we recommend configuring a maximum of 200 interfaces in SmartConsole. If the Security Gateway object contains more interfaces, use the applicable Management API to configure interfaces. See the Check Point Management API Reference. To ensure optimal API responsiveness, we recommend configuring a maximum of 600 interfaces with API. |
Layers in Access Control Policy |
251 and 231 |
Yes |
The maximum number of Policy Layers in an Access Control Policy is 251. A Security Gateway has a limit of 4900 kernel tables. Each Access Control Policy Layer Layer (set of rules) in a Security Policy. creates 21 kernel tables on the Security Gateway. Each Access Control Policy creates 40 global kernel tables on the Security Gateway (that apply to all Policy Layers). Therefore, the additional calculation is: (4900 tables - 40 tables) / 21 tables per Policy Layer = 231 Policy Layers. |
Smart-1 6000-L/6000-XL Sizing Recommendations and Limitations
See sk178325.
Maximum Supported Number of Interfaces on Security Gateway
The maximum number of interfaces supported (physical and virtual) is shown in this table.
Mode |
Max # of Interfaces |
Notes |
---|---|---|
Security Gateway |
1024 |
|
4096 |
Includes VLANs and Warp Interfaces |
|
250 |
|
Note - This table applies to Check Point Appliances and Open Servers.
Maximum Supported Number of Cluster Members
Cluster Type |
Maximum Supported Number of Cluster Members |
---|---|
5 |
|
13 |