Description
This command lets you initiate a manual cluster failover (see sk55081).
Syntax
Shell |
Command |
---|---|
Gaia Clish |
set cluster member admin down up |
Expert mode |
clusterXL_admin down up |
Example
Member2> show cluster state
Cluster Mode: High Availability (Active Up) with IGMP Membership
ID Unique Address Assigned Load State Name
1 192.168.20.176 0% STANDBY Member1 2 (local) 192.168.20.177 100% ACTIVE Member2
Active PNOTEs: None
Last member state change event: Event Code: CLUS-11482 State change: STANDBY -> ACTIVE Reason for state change: No other ACTIVE member has been found in the cluster Event time: Sun Jun 3 20:24:35 2018
Last cluster failover event: Transition to new ACTIVE: Member 1 -> Member 2 Reason: Interface eth1 is down (Cluster Control Protocol packets are not received) Event time: Sun Jun 3 20:24:35 2018
Cluster failover count: Failover counter: 261 Time of counter reset: Sun Jun 3 20:24:35 2018 (reboot)
Member2>
Member2> set cluster member admin down Setting member to administratively down state ... Member current state is DOWN Member2>
Member2> show cluster state
Cluster Mode: High Availability (Active Up) with IGMP Membership
ID Unique Address Assigned Load State Name
1 192.168.20.176 100% ACTIVE Member1 2 (local) 192.168.20.177 0% DOWN Member2
Active PNOTEs: ADMIN
Last member state change event: Event Code: CLUS-11144 State change: ACTIVE -> DOWN Reason for state change: ADMIN_DOWN PNOTE Event time: Sun Jun 3 20:27:19 2018
Last cluster failover event: Transition to new ACTIVE: Member 2 -> Member 1 Reason: ADMIN_DOWN PNOTE Event time: Sun Jun 3 20:27:19 2018
Cluster failover count: Failover counter: 262 Time of counter reset: Sun Jun 3 20:27:19 2018 (reboot)
Member2>
Member2> set cluster member admin up Setting member to normal operation ... Member current state is STANDBY Member2>
Member2> show cluster state
Cluster Mode: High Availability (Active Up) with IGMP Membership
ID Unique Address Assigned Load State Name
1 192.168.20.176 100% ACTIVE Member1 2 (local) 192.168.20.177 0% STANDBY Member2
Active PNOTEs: None
Last member state change event: Event Code: CLUS-11490 State change: DOWN -> STANDBY Reason for state change: There is already an ACTIVE member in the cluster (member 1) Event time: Sun Jun 3 20:27:44 2018
Last cluster failover event: Transition to new ACTIVE: Member 2 -> Member 1 Reason: ADMIN_DOWN PNOTE Event time: Sun Jun 3 20:27:19 2018
Cluster failover count: Failover counter: 262 Time of counter reset: Sun Jun 3 20:27:44 2018 (reboot)
Member2> |