Configuring Alerts for Security Group Member and Security Group Events (asg alert)
The "asg alert" command is an interactive wizard that configures alerts for Security Group Member and
These events include hardware failure, recovery, and performance-related events. You can create other general events.
An alert is sent when an event occurs. For example, when the value of a hardware resource is greater than the threshold.
The alert message includes the Site ID, Security Group Member ID, and/or unit ID.
The wizard has these options:
|
Option |
Description |
|---|---|
|
Full Configuration Wizard |
Creates a new alert. |
|
Edit Configuration |
Changes an existing alert. |
|
Show Configuration |
Shows existing alert configuration. |
|
Run Test |
Runs a test simulation to make sure that the alert works correctly. |
To create or change an alert:
|
Step |
Instructions |
|
|---|---|---|
|
1 |
Run in Gaia gClish of a Security Group:
|
|
|
2 |
Select Full Configuration Wizard or Edit Configuration. |
|
|
3 |
Select and configure these parameters as prompted by the wizard:
|
SMS Alert Configuration
|
Parameter |
Description |
|---|---|
|
SMS provider URL |
Fully qualified URL to your SMS provider. |
|
HTTP proxy and port |
Optional. Configure only if the Security Gateway requires a proxy server to reach the SMS provider. |
|
SMS rate limit |
Maximum number of SMS messages sent per hour. If there are too many messages, they can be combined together. |
|
SMS user text |
Custom prefix for SMS messages. |
Email Alert Configuration
|
Parameter |
Description |
|---|---|
|
SMTP server IP |
One or more SMTP servers to which the email alerts are sent. |
|
Email recipient addresses |
One or more recipient email address for each SMTP server. |
|
Periodic connectivity checks |
Tests run periodically to confirm connectivity with the SNMP servers. If there is no connectivity, alert messages are saved and sent in one email when connectivity is restored. |
|
Interval |
Interval, in minutes, between connectivity tests. |
|
Sender email address |
Email address of the sender for alerts. |
|
Subject |
Subject header text for the email alert. |
|
Body text |
User defined text for the alert message. |
SNMP Alert Configuration
Define one or more SNMP managers to get SNMP traps sent from the Security Gateway.
For each manager, configure these parameters:
|
Parameter |
Description |
|---|---|
|
SNMP manager name |
Unique name for the SNMP manager. |
|
SNMP manager IP |
IP address of the SNMP Manager (trap receiver). |
|
SNMP version |
SNMP version (v2c, v3). |
|
SNMP v3 user name |
User name for SNMP v3 authentication. |
|
SNMP v3 security level |
Security level for SNMP v3 authentication. |
|
SNMP v3 engine ID |
Unique SNMP v3 engine ID used by your system. The default is: |
|
SNMP v3 authentication protocol |
Authentication protocol (MD5 or SHA) for SNMP v3 authentication. |
|
SNMP v3 authentication password |
Authentication password for SNMP v3 authentication. |
|
SNMP v3 privacy protocol |
Privacy protocol (DES or AES) for SNMP v3 authentication. |
|
SNMP v3 privacy password |
Privacy password for SNMP v3 authentication. |
|
SNMP user text |
Custom text for SNMP trap messages. |
|
SNMP community string |
Community name. |
|
|
Notes:
|
System Event Types
You can select one or more event types:
-
One event type.
-
A comma-delimited list of more than one event type.
-
All event types.