Open Frames Download Complete PDF Send Feedback Print This Page

Previous

Next

Troubleshooting Failures with asg diag

This example shows how to use the asg diag command for troubleshooting a failed diagnostic test. In this case, the test shows that two fans are down and the CPU temperature exceeds its threshold. The output identifies the failed components.

> asg diag verify 2
------------------------------------------------------------------------------
| Tests Status                                                               |
------------------------------------------------------------------------------
| ID | Title              | Result | Reason                                  |
------------------------------------------------------------------------------
| System Components                                                          |
------------------------------------------------------------------------------
|  2 | Hardware           | Failed | (1)Chassis fan is down                  |
|    |                    |        | (2)Chassis fan exceeds threshold        |
|    |                    |        | (3)CPU exceeds threshold                |
------------------------------------------------------------------------------
| Tests Summary                                                              |
------------------------------------------------------------------------------
| Passed: 0/1 test                                                           |
| Run: "asg diag list 2" to view a complete list of failed tests             |
| Output file: /var/log/verifier_sum.2.2014-02-17_10-58-31.txt               |
------------------------------------------------------------------------------

> asg diag print 2
-----------------------------------------------------------------------------
| Hardware Monitor                                                          |
-----------------------------------------------------------------------------
| Sensor           | Location       | Value | Threshold | Units     | State |
-----------------------------------------------------------------------------
| Chassis 1                                                                 |
-----------------------------------------------------------------------------
| CMM              | bay 1          | 1     | 0         | <S,D>/<A>   | 1   |
| CMM              | bay 2          | 0     | 0         | <S,D>/<A>   | 1   |
| CPUtemp          | blade 1, CPU0  | 0     | 65        | Celsius     | 1   |
| CPUtemp          | blade 1, CPU1  | 0     | 65        | Celsius     | 1   |
| CPUtemp          | blade 2, CPU0  | 44    | 65        | Celsius     | 1   |
| CPUtemp          | blade 2, CPU1  | 41    | 65        | Celsius     | 1   |
| CPUtemp          | blade 3, CPU0  | 44    | 65        | Celsius     | 1   |
| CPUtemp          | blade 3, CPU1  | 40    | 65        | Celsius     | 1   |
| CPUtemp          | blade 4, CPU0  | 47    | 65        | Celsius     | 1   |
| CPUtemp          | blade 4, CPU1  | 43    | 65        | Celsius     | 1   |
| CPUtemp          | blade 5, CPU0  | 46    | 65        | Celsius     | 1   |
| CPUtemp          | blade 5, CPU1  | 42    | 65        | Celsius     | 1   |
| Fan              | bay 1, fan 1   | 0     | 11        | Speed Level | 0   |
| Fan              | bay 1, fan 2   | 0     | 11        | Speed Level | 0   |
| Fan              | bay 2, fan 1   | 15    | 11        | Speed Level | 1   |
| Fan              | bay 2, fan 2   | 15    | 11        | Speed Level | 1   |
| Fan              | bay 3, fan 1   | 15    | 11        | Speed Level | 1   |
| Fan              | bay 3, fan 2   | 15    | 11        | Speed Level | 1   |
| PowerConsumption | N/A            | 2471  | 4050      | Watts       | 1   |
| PowerUnit(AC)    | bay 1          | 0     | 0         | NA          | 1   |
| PowerUnit(AC)    | bay 2          | 0     | 0         | NA          | 1   |
| PowerUnit(AC)    | bay 3          | 0     | 0         | NA          | 1   |
| PowerUnit(AC)    | bay 4          | 0     | 0         | NA          | 0   |
| PowerUnit(AC)    | bay 5          | 0     | 0         | NA          | 0   |
| PowerUnitFan     | bay 1, fan 1   | 0     | 0         | NA          | 1   |
| PowerUnitFan     | bay 1, fan 2   | 0     | 0         | NA          | 1   |
| PowerUnitFan     | bay 2, fan 1   | 0     | 0         | NA          | 1   |
| PowerUnitFan     | bay 2, fan 2   | 0     | 0         | NA          | 1   |
| PowerUnitFan     | bay 3, fan 1   | 0     | 0         | NA          | 1   |
| PowerUnitFan     | bay 3, fan 2   | 0     | 0         | NA          | 1   |
| PowerUnitFan     | bay 4, fan 1   | 0     | 0         | NA          | 0   |
| PowerUnitFan     | bay 4, fan 2   | 0     | 0         | NA          | 0   |
| PowerUnitFan     | bay 5, fan 1   | 0     | 0         | NA          | 0   |
| PowerUnitFan     | bay 5, fan 2   | 0     | 0         | NA          | 0   |
| SSM              | bay 1          | 136   | 0         | Mbps        | 1   |
| SSM              | bay 2          | 128   | 0         | Mbps        | 1   |
-----------------------------------------------------------------------------
| Chassis 2                                                                 |
-----------------------------------------------------------------------------
| CMM              | bay 1          | 1     | 0         | <S,D>/<A>   | 1   |
| CMM              | bay 2          | 0     | 0         | <S,D>/<A>   | 1   |
| CPUtemp          | blade 1, CPU0  | 50    | 65        | Celsius     | 1   |
| CPUtemp          | blade 1, CPU1  | 64    | 65        | Celsius     | 1   |
| CPUtemp          | blade 2, CPU0  | 48    | 65        | Celsius     | 1   |
| CPUtemp          | blade 2, CPU1  | 64    | 65        | Celsius     | 1   |
| CPUtemp          | blade 3, CPU0  | 48    | 65        | Celsius     | 1   |
| CPUtemp          | blade 3, CPU1  | 64    | 65        | Celsius     | 1   |
| CPUtemp          | blade 4, CPU0  | 47    | 65        | Celsius     | 1   |
| CPUtemp          | blade 4, CPU1  | 74    | 65        | Celsius     | 1   |
| CPUtemp          | blade 5, CPU0  | 84    | 65        | Celsius     | 1   |
| CPUtemp          | blade 5, CPU1  | 71    | 65        | Celsius     | 1   |
| Fan              | bay 1, fan 1   | 4     | 11        | Speed Level | 1   |
| Fan              | bay 1, fan 2   | 4     | 11        | Speed Level | 1   |
| Fan              | bay 2, fan 1   | 4     | 11        | Speed Level | 1   |
| Fan              | bay 2, fan 2   | 4     | 11        | Speed Level | 1   |
| Fan              | bay 3, fan 1   | 4     | 11        | Speed Level | 1   |
| Fan              | bay 3, fan 2   | 4     | 11        | Speed Level | 1   |
|    .                                                                      |
|    .                                                                      |
-----------------------------------------------------------------------------
 



						

						
					
 
Top of Page ©2014 Check Point Software Technologies Ltd. All rights reserved. Download Complete PDF Send Feedback Print