Use asg alert an interactive wizard to configure alerts for SGM and Chassis events. Chassis events include hardware failure, recovery, and performance related events, and you can create other, general events.
An alert is sent when an event occurs, for example, when the value of a hardware resource is greater than the threshold. The alert message includes the Chassis ID, SGM ID and/or unit ID.
The wizard includes these options:
Option |
Description |
|---|---|
Full Configuration Wizard |
Create a new alert |
Edit Configuration |
Change an existing alert |
Show Configuration |
Show existing alert configurations |
Run Test |
Run a test simulation to make sure that the alert works correctly |
To create or change an alert:
> asg alert
Alert Parameters
Define one or more SNMP managers to get SNMP traps sent from the Security Gateway. For each manager, configure these parameters as prompted:
Note - Some parameters do not show, based on your settings.
Event types
You can select one or more event types:
all event types.-----------------------------------
1 | SGM State
2 | Chassis State
3 | Port State
4 | Pingable Hosts State
5 | System Monitor Daemon
6 | Route State
7 | Diagnostics
Hardware Monitor events:
8 | Fans
9 | SSM
10 | CMM
11 | Power Supplies
12 | CPU Temperature
Performance events:
13 | Concurrent Connections
14 | Connection Rate
15 | Packet Rate
16 | Throughput
17 | CPU Load
18 | Hard Drive Utilization
19 | Memory Utilization
Alert Modes