Error Types

This table shows some of the errors detected by asg diag verify.

Error Type

Error

Description

System health

Chassis <X> error

The Chassis quality grade is less than the defined threshold. We recommend that you correct this issue immediately.

Hardware

<Component> is missing

The component is not installed in the Chassis.

<Component> is down

The component is installed in the Chassis, but is inactive.

Resources

<Resource> capacity

The specified resource capacity is not sufficient. You can change the defined resource capacity.

<Resource> exceed threshold

The resource’s usage is greater than the defined threshold.

CPU type

Non compliant CPU type

At least one SGM CPU type is not configured in the list of compliant CPUs. You can define the compliant CPU types.

Security group

<Source> error

The information collected from this source is different between the SGMs.

<Sources> differ

The information collected from many sources is different.