Open Frames Download Complete PDF Send Feedback Print This Page

Previous

Next

Chassis Management Module (CMM) CLI

The Chassis Management Module (CMM) monitors and controls hardware modules in the Chassis. The CCM communicates with a dedicated SGM using SNMP. If a hardware sensor reports a problem, the CMM automatically takes action or sends a report. CMMs also have a Command Line Interface.

To connect to the active CMM:

  1. Connect to the serial port on the front panel of the CMM.
  2. In your terminal emulation program, set the baud rate to 9600.
  3. Enter admin for the user name and password.
  4. Open a telnet or SSH session from one of the SGMs.
  5. Ping these addresses:
    • 198.51.100.33
    • 198.51.100.233
  6. Telnet or SSH from the SGM to the active CMM.
  7. Enter admin for the user name and password.

To connect to the standby CMM:

  1. Connect to the active CMM.
  2. At the command prompt, run: ifconfig
  3. Record the IP Address for the USB interface.
  4. Telnet or SSH from the active CMM to the standby CMM with the IP from the table below.

Active CMM IP

Standby CMM IP

192.168.1.131

192.168.1.130

192.168.1.131

192.168.1.130

192.168.1.2

192.168.1.3

192.168.1.3

192.168.1.2

Related Topics

Logging CMM Diagnostic Information

Changing the CMM Administrator Password

Changing the Chassis Configuration

Chassis Management Module (CMM) CLI Commands

 
Top of Page ©2014 Check Point Software Technologies Ltd. All rights reserved. Download Complete PDF Send Feedback Print