Open Frames Download Complete PDF Send Feedback Print This Page

Previous

Next

SSM60

To run the validation test:

  1. Connect to the SSM using telnet.

    The default password is admin.

  2. Use Enable Mode:

    > en

  3. Show the running configuration:

    # show run

  4. Make sure that all applicable interfaces (downlinks and front panel ports) show the required packet size limit.

    # telnet 198.51.100.32

    Trying 198.51.100.32...

    Connected to 198.51.100.32.

    Escape character is '^]'.

    User Access Verification

    Password:

    FI_cp>en

    #show run

    .

    .

    .

    !

    interface 1/2/1

    flow-control disable

    packet-size-limit 9146

    !

 
Top of Page ©2014 Check Point Software Technologies Ltd. All rights reserved. Download Complete PDF Send Feedback Print