Build 1055
Released on 15 June 2025
|
PRJ-58051, MGMTPROD-387
|
NEW: Added support for using Network Groups in the "Install On" column in the NAT Policy view.
|
PRJ-59842
|
UPDATE: When the versioning feature flag is present, the Policy Insight button and tabs display according to Web SmartConsole command parameters. Otherwise, they appear using the legacy display logic.
|
PRJ-58515,
PMTR-111126
|
UPDATE: Added support for editing services in Custom Applications/Sites. Refer to R82 Quantum Security Management Administration Guide > Creating an Access Control Policy > The Columns of the Access Control Rule Base.
|
PRJ-59851,
PMTR-111722
|
UPDATE: The "Report Log to Check Point" option will no longer appear on Log cards. Refer to sk183026.
|
PRJ-59781
|
UPDATE: Resizable dialogs now maintain their last size setting after being closed and reopened.
|
PRJ-58677,
PMTR-110609
|
UPDATE: CME (Cloud Management Extension) is now integrated into SmartConsole, Web SmartConsole, and Smart-1 Cloud. This integration facilitates cloud-native connectivity between Check Point CloudGuard Network solutions and various cloud platforms. Refer to sk157492.
|
PRJ-58306,
PMTR-110121
|
UPDATE: AI Copilot can be undocked by clicking the button in the toolbar. The tab becomes a dialog that can be moved and resized, offering greater flexibility. Closing the dialog restores the Copilot tab in its original position.
|
PRJ-59441,
PRJ-59436
|
UPDATE: The side pane of AI Copilot and objects now has a minimum width and cannot be reduced further. You can still close the pane by clicking the buttons on the side or top.
|
PRJ-57889,
PRHF-36762
|
Loading the Indicators view and performing operations on IoC Feeds may cause SmartConsole to become unresponsive and slow.
|
PRJ-57649,
PRHF-34460
|
When selecting a rule in the Rule Base, the Logs tab at the bottom of the window may appear empty or display its content improperly.
|
PRJ-58809,
PRHF-37650
|
Despite the error message indicating a limit, more than five Security Gateway Objects can be selected as favorites in the Compliance Blade.
|
PRJ-59333, MGMTPROD-1249
|
In SmartConsole, in the Quantum Spark Cluster object, it is possible to configure an invalid subnet mask when editing the interfaces manually in the Topology table.
|
PRJ-58816, PMTR-110851
|
Configuring "Enhanced Link Selection" method may cause SmartConsole crash when adding a Next Hop IPv6 Address with specific masks.
|
PRJ-60912,
PMTR-112016
|
Upgrade of Quantum Spark firmware in SmartProvisioning GUI may be blocked with "No SmartLSM Profile with installed policy found for the selected firmware".
|
Build 1053
Released on 20 April 2025
|
PRJ-58371,
PMTR-110305
|
When opening the Licenses tab, an unclear message may be printed "The service is not available".
|
PRJ-57830,
PMTR-108283
|
During import of a Virtual Gateway from AWS and creating a TPI community with Cluster and AWS peers, a validation error may be displayed when selecting external IP: "The VPN community is configured to use 'Enhanced Link Selection'. For each VPN peer that participates in this VPN community, you must configure the same IP version (IPv4/IPv6) on at least one of the Enhanced Link Selection Interfaces".
|
Build 1051
Released on 27 January 2025
|
PRJ-57660,
SDWANM-2320,
PMTR-108672
|
When the Security Management has an additional NAT configuration in the SD-WAN policy (Infinity Portal), an indicating banner may not appear in SmartConsole NAT Rule Base. This is a cosmetic issue.
|
PRJ-56960,
PRJ-56893
|
After an update, a redundant "SmartConsole is up to date" pop-up message appears sporadically over another application, without any user-initiated check.
|
PRJ-56719,
PRHF-35645
|
When opening an Identity Provider object multiple times in SmartConsole, the view may display no data until SmartConsole is restarted. Refer to sk182620.
|
PRJ-57665,
PMTR-109351
|
|
PRJ-57114,
PRHF-35908
|
When fetching users from the LDAP Server and the Server that contains no users to fetch, SmartDashboard displays a misleading error message "SmartDashboard not able to connect to XXXX".
|
PRJ-57612,
PMTR-109247
|
When modifying Portal Accessibility settings, in the Security Gateway editor, in the Zero Phishing tab, if HTTPS Inspection is enabled for this Security Gateway, the Zero-Phishing feature gets disabled.
|