Critical Information for R82 Jumbo Hotfix Accumulator
| Issue | Resolved in | Affected Takes |
SK |
Reference |
|---|---|---|---|---|
|
After an upgrade to R82 Jumbo Hotfix Accumulator Take 41 in Maestro and Chassis environment with multiple Virtual Systems (VS’s), the disk may reach full capacity. |
|
Take 41, Take 43, Take 44 |
|
PRJ-65636 |
|
Quantum Maestro Orchestrator Gaia WebUI may become inaccessible after installing R82 Jumbo Hotfix Accumulator Take 41 or Take 43. |
Take 44 |
Take 41, Take 43 |
|
PRJ-63944 |
|
Certain User Space processes (for example, PDPD) become unresponsive when working in Firewall Kernel Space Mode. |
Take 43 |
Take 36, Take 39, Take 41 |
PRJ-63918 |
|
|
When there are a large number of SNDs operating with Intel NICs, the system may run low on available jumbo mbufs, leading to connectivity issues. |
Take 41 |
Take 25, Take 33, Take 34, Take 36, Take 39 |
sk183771 |
PRJ-63052 |
|
Backup file size on the Security Management Server grows after an upgrade. |
Take 41 |
Take 36, Take 39 |
PRJ-63369 |
|
|
In some scenarios, SmartConsole does not display logs from the Multi-Domain Log Server and Multi-Domain Log Modules after an upgrade to R82. |
Take 39 |
Take 25, Take 33, Take 34, Take 36 |
PRJ-62598 |
|
|
The CloudGuard Network Central License utility fails to distribute the license, if there are duplicate entries of the license on the Security Management Server. |
Take 39 |
Take 25, Take 33, Take 34, Take 36 |
PRJ-63299 |
|
|
In a VSNext setup, Virtual Gateways (except VS0) cannot establish SIC connectivity with the Security Management Server. |
Take 33 |
Take 25 |
|
PRJ-62112 |