MLS200

Important - Make sure that you are electromagnetically grounded when you perform these procedures. ESD (electrostatic discharge) can damage the appliance.

Removing a Storage Device

Legend

Item

Description

1

Storage device casing

2

Release latch

3

Ejector handle

Hot Swapping a Storage Device

The appliance uses RAID1 mirroring across both storage devices. This lets the appliance continue to work if there is a storage device failure.

The mirror rebuild is automatic. Both storage devices must be the same type.

To hot swap a storage device:

  1. Make sure that there is at least one fully synchronized storage device (state = ONLINE) in the system. For more information, see Monitoring RAID.

  2. When the system is up, remove the failed storage device:

    1. Move the release latch to the left.

      The extraction handle pops out.

    2. Hold the extraction handle and carefully pull the storage device casing to remove the storage device from the appliance.

      Important - Be careful when you pull the ejector handle to remove the storage device from the appliance. If you pull too hard on the ejector handle, it can break off from the storage device casing.

  3. Wait 15 seconds.

    The appliance recognizes that you removed a storage device. See example 2 in Monitoring RAID.

  4. Install a new storage device.

    1. Insert the replacement storage device into the slot.

    2. Push the extraction handle until it closes and the device clicks into position.

    Software RAID is activated and the appliance synchronizes the storage devices. The first synchronization can continue for over an hour until completed. If you reboot or turn off the appliance before the storage devices are synchronized, the synchronization starts again from the beginning at the next boot.

  5. Monitor the RAID status, see Monitoring RAID.

Monitoring RAID

You can monitor the RAID status of the storage devices on the appliance from Gaia Clish, Gaia Portal, or SNMP.

To monitor the RAID status from Gaia Clish:

  1. Log in to the appliance and open a command line.

  2. Run:
    raid_diagnostic

    The output shows data about the RAID and storage devices, with the percent of synchronization completed.

    DiskID:0 is the top storage device. DiskID:1 is the bottom storage device.

After you install a second storage device, the RAID State (in the VolumeID line) shows DEGRADED (this indicates that the drives are not synchronized). The DiskID:0 state shows ONLINE and the DiskID:1 state shows INITIALIZING.

After the RAID is synchronized, the RAID State (in the VolumeID line) shows OPTIMAL (this indicates that the drives are synchronized). The DiskID:0 and DiskID:1 state shows ONLINE.

Example 1 - RAID status for fully synchronized storage devices (disk size and vendor may vary):

Server123> raid_diagnostic
Raid status:
VolumeID:0 RaidLevel: RAID-1 NumberOfDisks:2 RaidSize:465GB State:OPTIMAL Flags:ENABLED
DiskID:0 DiskNumber:0 Vendor:ATA  ProductID:HGST HTE25050A7 Revision:GS2O Size:465GB State:ONLINE Flags:NONE
DiskID:1 DiskNumber:1 Vendor:ATA  ProductID:HGST HTE25050A7 Revision:GS2O Size:465GB State:ONLINE Flags:NONE

Example 2 - RAID status for one fully synchronized storage device and another device that was removed (disk size and vendor may vary):

Server123> raid_diagnostic
Raid status:
VolumeID:0 RaidLevel: RAID-1 NumberOfDisks:2 RaidSize:465GB State:DEGRADED Flags:VOLUME_INACTIVE
DiskID:0 DiskNumber:0 Vendor:NONE ProductID:NONE Revision:NONE Size:0GB State:MISSING Flags:NONE
DiskID:1 DiskNumber:1 Vendor:ATA  ProductID:HGST HTE25050A7 Revision:GS2O Size:465GB State:ONLINE Flags:NONE

To monitor the RAID status from the Gaia Portal:

  1. Log in to Gaia Portal.

  2. Select Maintenance > RAID Monitoring.

To monitor the RAID status from SmartConsole:

  1. Log in to SmartConsole.

  2. Scroll to the end of the window and click RAID Volumes.

    The window shows the volume and disk information.

To monitor the RAID status with SNMP:

Set up SNMP traps to send information about the RAID.
Use OID: 1.3.6.1.4.1.2620.1.6.7.7